Difference between revisions of "User:Jhurley/sandbox"

From Enviro Wiki
Jump to: navigation, search
(Introduction)
 
(528 intermediate revisions by the same user not shown)
Line 1: Line 1:
==PFAS Treatment by Electrical Discharge Plasma==
+
==Munitions Constituents – Sample Extraction and Analytical Techniques==  
Plasma-based water treatment is a technology that, using only electricity, converts water into a mixture of highly reactive species including OH•, O, H•, HO<sub>2</sub>•, O<sub>2</sub>•<sup>‒</sup>, H<sub>2</sub>, O<sub>2</sub>, H<sub>2</sub>O<sub>2</sub> and aqueous electrons (e<sup>‒</sup><sub>aq</sub>), called a plasma<ref name="Sunka1999">Sunka, P., Babický, V., Clupek, M., Lukes, P., Simek, M., Schmidt, J., and Cernak, M., 1999. Generation of Chemically Active Species by Electrical Discharges in Water. Plasma Sources Science and Technology, 8(2), pp. 258-265. [https://doi.org/10.1088/0963-0252/8/2/006 DOI: 10.1088/0963-0252/8/2/006]</ref><ref name="MededovicThagard2009">Mededovic Thagard, S., Takashima, K., and Mizuno, A., 2009. Chemistry of the Positive and Negative Electrical Discharges Formed in Liquid Water and Above a Gas-Liquid Surface. Plasma Chemistry and Plasma Processing, 29(6), pp.455-473. [https://doi.org/10.1007/s11090-009-9195-x DOI: 10.1007/s11090-009-9195-x]</ref>. These highly reactive species rapidly and non-selectively degrade [[Wikipedia: Volatile organic compound |volatile organic compounds (VOCs)]]<ref name="Du2019">Du, C., Gong, X., and Lin, Y., 2019. Decomposition of volatile organic compounds using corona discharge plasma technology. Journal of the Air and Waste Management Association, 69(8), pp.879-899.  [https://doi.org/10.1080/10962247.2019.1582441 DOI: 10.1080/10962247.2019.1582441]  [https://www.tandfonline.com/doi/full/10.1080/10962247.2019.1582441 Open access article.]</ref>, [[1,4-Dioxane | 1,4-dioxane]]<ref name="Xiong2019">Xiong, Y., Zhang, Q., Wandell, R., Bresch, S., Wang, H., Locke, B.R. and Tang, Y., 2019. Synergistic 1,4-Dioxane Removal by Non-Thermal Plasma Followed by Biodegradation. Chemical Engineering Journal, 361, pp.519-527. [https://doi.org/10.1016/J.CEJ.2018.12.094 DOI: 10.1016/J.CEJ.2018.12.094]</ref><ref name="Ni2013">Ni, G.H., Zhao, Y., Meng, Y.D., Wang, X.K., and Toyoda, H., 2013. Steam plasma jet for treatment of contaminated water with high-concentration 1,4-dioxane organic pollutants. Europhysics Letters, 101(4), p.45001. [https://doi.org/10.1209/0295-5075/101/45001 DOI: 10.1209/0295-5075/101/45001]</ref>, and a broad spectrum of [[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS) | per- and polyfluoroalkyl substances (PFAS)]] including perfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), and short-chain PFAS<ref name="Stratton2015">Stratton, G.R., Bellona, C.L., Dai, F., Holsen, T.M. and Mededovic Thagard, S., 2015. Plasma-Based Water Treatment: Conception and Application of a New General Principle for Reactor Design. Chemical Engineering Journal, 273, pp.543-550. [https://doi.org/10.1016/j.cej.2015.03.059 DOI: 10.1016/j.cej.2015.03.059]</ref><ref name="Singh2019a">Singh, R.K., Multari, N., Nau-Hix, C., Anderson, R.H., Richardson, S.D., Holsen, T.M. and Mededovic Thagard, S., 2019. Rapid Removal of Poly- and Perfluorinated Compounds from Investigation-Derived Waste (IDW) in a Pilot-Scale Plasma Reactor. Environmental Science and Technology, 53(19), pp.11375-11382. [https://doi.org/10.1021/acs.est.9b02964 DOI: 10.1021/acs.est.9b02964]</ref><ref name="Singh2019b">Singh, R.K., Fernando, S., Baygi, S.F., Multari, N., Mededovic Thagard, S., and Holsen, T.M., 2019. Breakdown Products from Perfluorinated Alkyl Substances (PFAS) Degradation in a Plasma-Based Water Treatment Process. Environmental Science and Technology, 53(5), pp.2731-2738. [https://doi.org/10.1021/acs.est.8b07031 DOI: 10.1021/acs.est.8b07031]</ref>. A plasma reactor can simultaneously oxidize and reduce organics by producing a mixture of hydroxyl radicals and aqueous electrons, the latter of which act as strong reducing agents and could be the key species in removing PFAS and other non-oxidizable compounds. Additionally, the plasma process produces no residual waste and requires no chemical additions, although adding surfactants or injecting inert gas into the liquid phase can increase interfacial PFAS concentrations, exposing more of the PFAS to the plasma and therefore increasing removal efficiency.  
+
Munitions Constituents, including [[Wikipedia: Insensitive munition | insensitive munitions]] (IM), are a broad category of compounds which, in areas where manufactured or used, can be found in a variety of environmental matrices (waters, soil, and tissues). This presents an analytical challenge when a variety of these munitions are to be quantified. This article discusses sample extraction methods for each typical sample matrix (high level water, low level water, soil and tissue) as well as the accompanying [[Wikipedia: High-performance liquid chromatography | HPLC]]-UV analytical method for 27 compounds of interest (legacy munitions, insensitive munitions, and surrogates).  
 +
 
 
<div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
 
<div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
  
 
'''Related Article(s):'''
 
'''Related Article(s):'''
*[[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS)]]
+
 
*[[PFAS Ex Situ Water Treatment]]
+
*[[Munitions Constituents]]
  
 
'''Contributor(s):'''  
 
'''Contributor(s):'''  
*Dr. Selma Mededovic Thagard
+
 
*Dr. Thomas Holsen
+
*Dr. Austin Scircle
*Dr. Stephen Richardson, P.E
 
*Poonam Kulkarni, P.E.
 
*Dr. Blossom Nzeribe
 
  
 
'''Key Resource(s):'''
 
'''Key Resource(s):'''
* [https://pfas-1.itrcweb.org/12-treatment-technologies/#12_2  PFAS – Per- and Polyfluoroalkyl Substances: 12.2 Field-Implemented Liquids Treatment Technologies. Interstate Technology Regulatory Council (ITRC).]  See also: [https://pfas-1.itrcweb.org/12-treatment-technologies/#12_5 12.5 Limited Application and Developing Liquids Treatment Technologies].
 
  
* Physico-Chemical Processes for the Treatment of Per- And Polyfluoroalkyl Substances (PFAS): A review28<ref name="Nzeribe2019">Nzeribe, B.N., Crimi, M., Mededovic Thagard, S. and Holsen, T.M., 2019. Physico-Chemical Processes for the Treatment of Per- And Polyfluoroalkyl Substances (PFAS): A review. Critical Reviews in Environmental Science and Technology, 49(10), pp.866-915. [https://doi.org/10.1080/10643389.2018.1542916 DOI: 10.1080/10643389.2018.1542916]</ref>
+
*[https://www.epa.gov/sites/default/files/2015-07/documents/epa-8330b.pdf USEPA Method 8330B]<ref name= "8330B">United States Environmental Protection Agency (USEPA), 2006. EPA Method 8330B (SW-846) Nitroaromatics, Nitramines, and Nitrate Esters by High Performance Liquid Chromatography (HPLC), Revision 2. [https://www.epa.gov/esam/epa-method-8330b-sw-846-nitroaromatics-nitramines-and-nitrate-esters-high-performance-liquid USEPA Website]&nbsp; &nbsp;[[Media: Epa-2006-method-8330b.pdf | EPA Method 8330b]]</ref>
  
* Low Temperature Plasma for Biology, Hygiene, and Medicine: Perspective and Roadmap<ref name="Laroussi2021">Laroussi, M., Bekeschus, S., Keidar, M., Bogaerts, A., Fridman, A., Lu, X.P., Ostrikov, K.K., Hori, M., Stapelmann, K., Miller, V., Reuter, S., Laux, C., Mesbah, A., Walsh, J., Jiang, C., Mededovic Thagard, S., Tanaka, H., Liu, D.W., Yan, D., and Yusupov, M., 2021. Low Temperature Plasma for Biology, Hygiene, and Medicine: Perspective and Roadmap. IEEE Transactions on Radiation and Plasma Medical Sciences. [https://doi.org/10.1109/TRPMS.2021.3135118 DOI: 10.1109/TRPMS.2021.3135118] [https://ieeexplore.ieee.org/abstract/document/9650590 Open access article.]</ref>
+
*Methods for simultaneous quantification of legacy and insensitive munition (IM) constituents in aqueous, soil/sediment, and tissue matrices<ref name="CrouchEtAl2020">Crouch, R.A., Smith, J.C., Stromer, B.S., Hubley, C.T., Beal, S., Lotufo, G.R., Butler, A.D., Wynter, M.T., Russell, A.L., Coleman, J.G., Wayne, K.M., Clausen, J.L., Bednar, A.J., 2020. Methods for simultaneous determination of legacy and insensitive munition (IM) constituents in aqueous, soil/sediment, and tissue matrices. Talanta, 217, Article 121008. [https://doi.org/10.1016/j.talanta.2020.121008 doi: 10.1016/j.talanta.2020.121008]&nbsp; &nbsp;[[Media: CrouchEtAl2020.pdf | Open Access Manuscript.pdf]]</ref>
  
 
==Introduction==
 
==Introduction==
Plasma processing plays an essential role in various industrial applications such as semiconductor fabrication, polymer functionalization, chemical synthesis, agriculture and food safety, health industry, and hazardous waste management<ref name="VanVeldhuizen2002">Van Veldhuizen, E.M., and Rutgers, W.R., 2002. Pulsed Positive Corona Streamer Propagation and Branching. Journal of Physics D: Applied Physics, 35(17), p.2169.  [https://doi.org/10.1088/0022-3727/35/17/313 DOI: 10.1088/0022-3727/35/17/313]</ref><ref name="Yang">Yang, Y., Cho, Y.I. and Fridman, A., 2012. Plasma Discharge in Liquid: Water Treatment and Applications. CRC press. ISBN: 978-1-4398-6623-8  [https://doi.org/10.1201/b11650 DOI: 10.1201/b11650]</ref><ref name="Rezaei2019">Rezaei, F., Vanraes, P., Nikiforov, A., Morent, R., and De Geyter, N., 2019. Applications of Plasma-Liquid Systems: A Review. Materials, 12(17), article 2751, 69 pp. [https://doi.org/10.3390/ma12172751 DOI: 10.3390/ma12172751]&nbsp;&nbsp;   [https://www.mdpi.com/1996-1944/12/17/2751 Open access article].</ref><ref name="Herianto2021">Herianto, S., Hou, C.Y., Lin, C.M., and Chen, H.L., 2021. Nonthermal plasma-activated water: A comprehensive review of this new tool for enhanced food safety and quality. Comprehensive Reviews in Food Science and Food Safety, 20(1), pp. 583-626. [https://doi.org/10.1111/1541-4337.12667 DOI: 10.1111/1541-4337.12667]</ref>. Plasma is a gaseous state of matter consisting of charged particles, metastable-state molecules or atoms, and free radicals. Depending on the energy or temperature of the electrons, compared with the temperature of the background gas, plasmas can be classified as thermal or non-thermal. In thermal plasma, an example of which is an electrical arc, individual species’ temperatures typically exceed several thousand kelvins (K). Non-thermal plasmas are formed using less power with temperatures ranging from ambient to approximately 1000 K<ref name="Jiang2014">Jiang, B., Zheng, J., Qiu, S., Wu, M., Zhang, Q., Yan, Z. and Xue, Q., 2014. Review on Electrical Discharge Plasma Technology for Wastewater Remediation. Chemical Engineering Journal, 236, pp. 348–368. [https://doi.org/10.1016/j.cej.2013.09.090 DOI: 10.1016/j.cej.2013.09.090]</ref>. An example of a non-thermal plasma is a dielectric barrier discharge used for commercial ozone generation.  
+
{| class="wikitable mw-collapsible" style="float:left; margin-right:20px; text-align:center;"
 +
|+Table 1. Analyte list with acronyms and CAS numbers.  
 +
|-
 +
!Compound
 +
! Acronym
 +
!CAS Number
 +
|-
 +
| 1,2-Dinitrobenzene (surrogate) ||'''1,2-DNB (surr.)''' || 528-29-0
 +
|-
 +
| 1,3-Dinitrobenzene || 1,3-DNB || 99-65-0
 +
|-
 +
| 1,3,5-Trinitrobenzene || 1,3,5-TNB || 99-35-4
 +
|-
 +
| 1,4-Dinitrobenzene || '''1,4-DNB (surr.)''' || 100-25-4
 +
|-
 +
| 2-Amino-4,6-dinitrotoluene || 2-Am-4,6-DNT || 35572-78-2
 +
|-
 +
| 2-Nitrophenol || '''2-NP''' || 88-75-5
 +
|-
 +
| 2-Nitrotoluene || 2-NT || 88-72-2
 +
|-
 +
| 2,4-Dinitrophenol || '''2,4-DNP''' || 51-28-5
 +
|-
 +
| 2,4-Dinitrotoluene || 2,4-DNT || 121-14-2
 +
|-
 +
| 2,4,6-Trinitrophenol || '''Picric Acid (PA)''' || 88-89-1
 +
|-
 +
| 2,4,6-Trinitrotoluene || 2,4,6-TNT || 118-96-7
 +
|-
 +
| 2,6-Dinitrotoluene || 2,6-DNT || 606-20-2
 +
|-
 +
| 3-Nitrotoluene || 3-NT || 99-08-1
 +
|-
 +
| 3,5-Dinitroaniline || 3,5-DNA || 618-87-1
 +
|-
 +
| 4-Amino-2,6-dinitrotoluene || 4-Am-2,6-DNT || 19406-51-0
 +
|-
 +
| 4-Nitrophenol || '''4-NP''' || 100-02-7
 +
|-
 +
| 4-Nitrotoluene || 4-NT || 99-99-0
 +
|-
 +
| 2,4-Dinitroanisole || '''DNAN''' || 119-27-7
 +
|-
 +
| Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine || HMX || 2691-41-0
 +
|-
 +
| Nitrobenzene || NB || 98-95-3
 +
|-
 +
| Nitroglycerine || NG || 55-63-0
 +
|-
 +
| Nitroguanidine || '''NQ''' || 556-88-7
 +
|-
 +
| 3-Nitro-1,2,4-triazol-5-one || '''NTO''' || 932-64-9
 +
|-
 +
| ''ortho''-Nitrobenzoic acid || '''''o''-NBA (surr.)''' || 552-16-9
 +
|-
 +
| Pentaerythritol tetranitrate || PETN || 78-11-5
 +
|-
 +
| Hexahydro-1,3,5-trinitro-1,3,5-triazine || RDX || 121-82-4
 +
|-
 +
| N-Methyl-N-(2,4,6-trinitrophenyl)nitramide || Tetryl || 479-45-8
 +
|-
 +
| colspan="3" style="background-color:white;" | Note: Analytes in '''bold''' are not identified by EPA Method 8330B.
 +
|}
 +
[[File: ScircleFig1.png | thumb | 400px | Figure 1. Primary Method labeled chromatograms]]
 +
[[File: ScircleFig2.png | thumb | 400px | Figure 2. Secondary Method labeled chromatograms]]
 +
The&nbsp;primary&nbsp;intention of the analytical methods presented here is to support the monitoring of legacy and insensitive munitions contamination on test and training ranges, however legacy and insensitive munitions often accompany each other at demilitarization facilities, manufacturing facilities, and other environmental sites. Energetic materials typically appear on ranges as small, solid particulates and due to their varying functional groups and polarities, can partition in various environmental compartments<ref>Walsh, M.R., Temple, T., Bigl, M.F., Tshabalala, S.F., Mai, N. and Ladyman, M., 2017. Investigation of Energetic Particle Distribution from High‐Order Detonations of Munitions. Propellants, Explosives, Pyrotechnics, 42(8), pp. 932-941. [https://doi.org/10.1002/prep.201700089 doi: 10.1002/prep.201700089]</ref>. To ensure that contaminants are monitored and controlled at these sites and to sustainably manage them a variety of sample matrices (surface or groundwater, process waters, soil, and tissues) must be considered. (Process water refers to water used during industrial manufacturing or processing of legacy and insensitive munitions.) Furthermore, additional analytes must be added to existing methodologies as the usage of IM compounds changes and as new degradation compounds are identified.  Of note, relatively new IM formulations containing [[Wikipedia: Nitrotriazolone | NTO]], [[Wikipedia: 2,4-Dinitroanisole | DNAN]], and [[Wikipedia: Nitroguanidine | NQ]] are seeing use in [[Wikipedia: IMX-101 | IMX-101]], IMX-104, Pax-21 and Pax-41 (Table 1)<ref>Mainiero, C. 2015. Picatinny Employees Recognized for Insensitive Munitions. U.S. Army, Picatinny Arsenal Public Affairs. [https://www.army.mil/article/148873/picatinny_employees_recognized_for_insensitive_munitions Open Access Press Release]</ref><ref>Frem, D., 2022. A Review on IMX-101 and IMX-104 Melt-Cast Explosives: Insensitive Formulations for the Next-Generation Munition Systems. Propellants, Explosives, Pyrotechnics, 48(1), e202100312. [https://doi.org/10.1002/prep.202100312 doi: 10.1002/prep.202100312]</ref>.
  
Plasma that is applied in water treatment (Figure 1) is typically non-thermal, which offers high-energy process efficiency and selectivity<ref name="Jiang2014"/><ref name="Magureanu2018">Magureanu, M., Bradu, C., and Parvulescu, V.I., 2018. Plasma Processes for the Treatment of Water Contaminated with Harmful Organic Compounds. Journal of Physics D: Applied Physics, 51(31), p. 313002. [https://doi.org/10.1088/1361-6463/aacd9c DOI:    10.1088/1361-6463/aacd9c]</ref>. Since the 1980s when the first plasma reactor was utilized to oxidize a dye<ref name="Clements1987">Clements, J.S., Sato, M., and Davis, R.H., 1987. Preliminary Investigation of Prebreakdown Phenomena and Chemical Reactions Using a Pulsed High-Voltage Discharge in Water. IEEE Transactions on Industry Applications, IA-23(2), pp. 224-235.  [https://doi.org/10.1109/TIA.1987.4504897 DOI: 10.1109/TIA.1987.4504897]</ref>, over a hundred different plasma reactors have been developed to treat a range of contaminants of environmental importance including biological species. Examples include treatment of pharmaceuticals, volatile organic compounds (VOCs), 1,4-dioxane, herbicides, pesticides, warfare agents, bacteria, yeasts and viruses using direct-in-liquid discharges with and without bubbles and discharges in a gas over and contacting the surface of a liquid. Different excitation sources including AC, nanosecond pulsed and DC voltages have been utilized to produce pulsed corona, corona-like, spark, arc, and glow discharges, among other discharge types. Many reviews of plasma processing for water treatment applications have recently been published<ref name="Zeghioud2020">Zeghioud, H., Nguyen-Tri, P., Khezami, L., Amrane, A., and Assadi, A.A., 2020. Review on Discharge Plasma for Water Treatment: Mechanism, Reactor Geometries, Active Species and Combined Processes. Journal of Water Process Engineering, 38, p.101664. [https://doi.org/10.1016/j.jwpe.2020.101664 DOI: 10.1016/j.jwpe.2020.101664]</ref><ref name="Murugesan2020">Murugesan, P., Evanjalin Monica, V., Moses, J.A., and Anandharamakrishnan, C., 2020. Water Decontamination Using Non-Thermal Plasma: Concepts, Applications, and Prospects. Journal of Environmental Chemical Engineering, 8(5), p. 104377. [https://doi.org/10.1016/j.jece.2020.104377 DOI: 10.1016/j.jece.2020.104377]</ref>.  
+
Sampling procedures for legacy and insensitive munitions are identical and utilize multi-increment sampling procedures found in USEPA Method 8330B Appendix A<ref name= "8330B"/>. Sample hold times, subsampling and quality control requirements are also unchanged. The key differences lie in the extraction methods and instrumental methods. Briefly, legacy munitions analysis of low concentration waters uses a single cartridge reverse phase [[Wikipedia: Solid-phase extraction | SPE]] procedure, and [[Wikipedia: Acetonitrile | acetonitrile]] (ACN) is used for both extraction and [[Wikipedia: Elution | elution]] for aqueous and solid samples<ref name= "8330B"/><ref>United States Environmental Protection Agency (USEPA), 2007. EPA Method 3535A (SW-846) Solid-Phase Extraction (SPE), Revision 1. [https://www.epa.gov/esam/epa-method-3535a-sw-846-solid-phase-extraction-spe USEPA Website]&nbsp; &nbsp;[[Media: epa-3535a.pdf | Method 3535A.pdf]]</ref>. An [[Wikipedia: High-performance_liquid_chromatography#Isocratic_and_gradient_elution | isocratic]] separation via reversed-phase C-18 column with 50:50 methanol:water mobile phase or a C-8 column with 15:85 isopropanol:water mobile phase is used to separate legacy munitions<ref name= "8330B"/>. While these procedures are sufficient for analysis of legacy munitions, alternative solvents, additional SPE cartridges, and a gradient elution are all required for the combined analysis of legacy and insensitive munitions.  
  
Plasma-based water treatment (PWT) owes its strong oxidation and disinfection capabilities to the production of reactive oxidative species (ROS), primarily OH radicals, atomic oxygen, singlet oxygen and hydrogen peroxide. The process also produces reductive species such as solvated electrons and reactive nitrogen species (RNS) when nitrogen and oxygen are present in the discharge. This process has the advantage of synergistic effects of high electric fields, UV/VUV light emissions and in some cases shockwave formation in a liquid. It requires no chemical additions, and can be optimized for batch or continuous processing.  
+
Previously, analysis of legacy and insensitive munitions required multiple analytical techniques, however the methods presented here combine the two munitions categories resulting in an HPLC-UV method and accompanying extraction methods for a variety of common sample matrices. A secondary HPLC-UV method and a HPLC-MS method were also developed as confirmatory methods. The methods discussed in this article were validated extensively by single-blind round robin testing and subsequent statistical treatment as part of ESTCP [https://serdp-estcp.mil/projects/details/d05c1982-bbfa-42f8-811d-51b540d7ebda ER19-5078]. Wherever possible, the quality control criteria in the Department of Defense Quality Systems Manual for Environmental Laboratories were adhered to<ref>US Department of Defense and US Department of Energy, 2021. Consolidated Quality Systems Manual (QSM) for Environmental Laboratories, Version 5.4. 387 pages. [https://www.denix.osd.mil/edqw/denix-files/sites/43/2021/10/QSM-Version-5.4-FINAL.pdf Free Download]&nbsp; &nbsp;[[Media: QSM-Version-5.4.pdf | QSM Version 5.4.pdf]]</ref>. Analytes included in the methods presented here are found in Table&nbsp;1.
  
==Fundamentals of Sediment Risk Assessment==
+
The chromatograms produced by the primary and secondary HPLC-UV methods are shown in Figure 1 and Figure 2, respectively. Chromatograms for each detector wavelength used are shown (315, 254, and 210 nm).
[[File: SedRiskFig1.PNG | thumb |700px|Figure 1. Schematic of the sediment risk assessment process]]
 
Whereas there is strong evidence of anthropogenic impacts on the benthic community at many sediment sites, the degree of toxicity (or even its presence or absence) cannot be predicted with absolute certainty using contaminant concentrations alone<ref name="Apitz2011"/>. A sediment ERA should include lines of evidence (LOEs) derived from several different investigations<ref name="Wenning2005"/>. One common approach to develop several of these LOEs in a decision framework is the triad approach. Triad-based assessment frameworks require evidence based on sediment chemistry, toxicity, and benthic community structure (possibly including evidence of bioaccumulation) to designate sediment as toxic and requiring management or control<ref name="Chapman1996">Chapman, P.M., Paine, M.D., Arthur, A.D., Taylor, L.A., 1996. A triad study of sediment quality associated with a major, relatively untreated marine sewage discharge. Marine Pollution Bulletin 32(1), pp. 47–64.  [https://doi.org/10.1016/0025-326X(95)00108-Y DOI: 10.1016/0025-326X(95)00108-Y]</ref>. In some decision frameworks, particularly those used to establish and rank risks in national or regional programs, all components of the triad are carried out simultaneously, with the various LOEs combined to support weight of evidence (WOE) decision making. In other frameworks, LOEs are tiered to minimize costs by collecting only the data required to make a decision and leaving some potential consequences and uncertainties unresolved.
 
  
Figure 1 provides an overview of a sediment risk assessment process. The first step, and a fundamental requirement, in sediment risk assessment, involves scoping and planning prior to undertaking work. This is important for optimizing the available assessment resource and conducting an assessment at the appropriate level of detail that is transparent and free, to the extent possible, of any bias or preconceived beliefs concerning the outcome<ref name="Hill2000">Hill, R.A., Chapman, P.M., Mann, G.S. and Lawrence, G.S., 2000. Level of Detail in Ecological Risk Assessments. Marine Pollution Bulletin, 40(6), pp. 471-477. [https://doi.org/10.1016/S0025-326X(00)00036-9 DOI: 10.1016/S0025-326X(00)00036-9]</ref>.
+
==Extraction Methods==
 +
[[File: ScircleFig3.PNG |thumb|400px|Figure 3. Triple cartridge SPE setup]]
 +
[[File: ScircleFig4.PNG |thumb|400px|Figure 4. A flow chart of the soil extraction procedure]]
 +
===High&nbsp;Concentration&nbsp;Waters (> 1 ppm)===
 +
Aqueous samples suspected to contain the compounds of interest at concentrations detectable without any extraction or pre-concentration are suitable for analysis by direct injection. The method deviates from USEPA Method 8330B by adding a pH adjustment and use of MeOH rather than ACN for dilution<ref name= "8330B"/>. The pH adjustment is needed to ensure method accuracy for ionic compounds (like NTO or PA) in basic samples. A solution of 1% HCl/MeOH is added to both acidify and dilute the samples to a final acid concentration of 0.5% (vol/vol) and a final solvent ratio of 1:1 MeOH/H<sub><small>2</small></sub>O. The direct injection samples are then ready for analysis.
  
===Screening-Level Risk Assessment (SLRA)===
+
===Low Concentration Waters (< 1 ppm)===
Technical guidance in many countries strongly encourages sediment risk assessment to begin with a Screening-Level Risk Assessment (SLRA)<ref name="USEPA2005"/><ref name="Tarazona2014"/><ref name="Fletcher2008"/>. The SLRA is a simplified risk assessment conducted using limited data and often assuming certain, generally conservative and generic, sediment characteristics, sediment contaminant levels, and exposure parameters in the absence of sufficient readily available information<ref name="Hope2006">Hope, B.K., 2006. An examination of ecological risk assessment and management practices. Environment International, 32(8), pp. 983-995.  [https://doi.org/10.1016/j.envint.2006.06.005 DOI: 10.1016/j.envint.2006.06.005]</ref><ref name="Weinstein2010">Weinstein, J.E., Crawford, K.D., Garner, T.R. and Flemming, A.J., 2010. Screening-level ecological and human health risk assessment of polycyclic aromatic hydrocarbons in stormwater detention pond sediments of Coastal South Carolina, USA. Journal of Hazardous Materials, 178(1-3), pp. 906-916.  [https://doi.org/10.1016/j.jhazmat.2010.02.024 DOI: 10.1016/j.jhazmat.2010.02.024]</ref><ref name="Rak2008">Rak, A., Maly, M.E., Tracey, G., 2008. A Guide to Screening Level Ecological Risk Assessment, TG-090801. Tri-Services Ecological Risk Assessment Working Group (TSERAWG), U.S. Army Biological Technical Assistance Group (BTAG), Aberdeen Proving Ground, MD. 26 pp.  [https://usaphcapps.amedd.army.mil/erawg/SLERA.pdf Free Download]&nbsp;&nbsp; [[Media: Rak2008.pdf | Report.pdf]]</ref><ref name="USEPA2001">US Environmental Protection Agency (USEPA), 2001. ECO Update. The Role of Screening-Level Risk Assessments and Refining Contaminants of Concern in Baseline Ecological Risk Assessments. EPA 540/F-01/014. Washington, D.C. [https://www.epa.gov/sites/default/files/2015-09/documents/slera0601.pdf  Website]&nbsp;&nbsp; [[Media: EPA 540_F-01_014.pdf  | Report.pdf]]</ref>.
+
Aqueous samples suspected to contain the compounds of interest at low concentrations require extraction and pre-concentration using solid phase extraction (SPE). The SPE setup described here uses a triple cartridge setup shown in Figure 3. Briefly, the extraction procedure loads analytes of interest onto the cartridges in this order: Strata<sup><small>TM</small></sup> X, Strata<sup><small>TM</small></sup> X-A, and Envi-Carb<sup><small>TM</small></sup>. Then the cartridge order is reversed, and analytes are eluted via a two-step elution, resulting in 2 extracts (which are combined prior to analysis). Five milliliters of MeOH is used for the first elution, while 5 mL of acidified MeOH (2% HCl) is used for the second elution. The particular SPE cartridges used are noncritical so long as cartridge chemistries are comparable to those above.  
  
The analysis is often semi-quantitative, and typically includes comparisons of various chemical and physical sediment conditions to threshold limits established in national or international regulations or by generally accepted scientific interpretations. US technical guidance encourages the comparison of contaminant measurements in water, sediment, or soil to National Oceanographic and Atmospheric Administration (NOAA) sediment screening quick reference tables, or SQuiRT cards, which list quality guidelines from a range of sources, based on differing narrative intent<ref name="Buchman2008">Buchman, M.F., 2008. Screening Quick Reference Tables (SQuiRTs), NOAA OR&R Report 08-1. National Oceanographic and Atmospheric Administration (NOAA), Coastal Protection and Restoration Protection Division. 34 pp. [https://repository.library.noaa.gov/view/noaa/9327  website]&nbsp;&nbsp; [[Media: SQuiRTs2008.pdf | Report.pdf]]</ref>.
+
{| class="wikitable mw-collapsible" style="float:left; margin-right:20px; text-align:center;"
 +
|+Table 2. Primary HPLC-UV mobile phase gradient method concentrations
 +
|-
 +
| colspan="5" style="background-color:white;"| Method run time = 48 minutes; Column temperature = 25&deg;C<br>Injection volume = 50 &mu;L; Flow rate = 1.0 mL/min<br>Detector wavelengths = 210, 254, and 310 nm
 +
|-
 +
! Time<br>(min)
 +
! Reagent Water<br>(%)
 +
! MeOH<br>(%)
 +
! 0.1% TFA/Water<br>(%)
 +
! ACN<br>(%)
 +
|-
 +
| 0.00 || 89 || 3 || 3 || 5
 +
|-
 +
| 2.00 || 89 || 3 || 3 || 5
 +
|-
 +
| 2.20 || 52 || 40 || 3 || 5
 +
|-
 +
| 12.5 || 52 || 40 || 3 || 5
 +
|-
 +
| 19.0 || 57 ||35 || 3 || 5
 +
|-
 +
| 28.0 || 48 || 44 || 3 || 5
 +
|-
 +
| 32.0 || 48 || 44 || 3 || 5
 +
|-
 +
| 44.0 || 32 || 60 || 3 || 5
 +
|-
 +
| 44.1 || 89 || 3 || 3 || 5
 +
|-
 +
| 48.0 || 89 || 3 || 3 || 5
 +
|}
  
The screening level approach is intended to minimize the chances of concluding that there is no risk when, in fact, risk may exist. Thus, the results of an SLRA may indicate contaminants or sediments in certain locations in the original study area initially thought to be of concern are acceptable (i.e., contaminant levels are below threshold levels), or that contaminant levels are high enough to indicate immediate action without further assessment (e.g., contaminant levels are well above probable-effects guidelines). In other cases, or at other locations, SLRA may indicate the need for further examination. Further study may apply site-specific, rather than generic and conservative assumptions, to reduce uncertainty.  
+
===Soils=== 
 +
Soil collection, storage, drying and grinding procedures are identical to the USEPA Method 8330B procedures<ref name= "8330B"/>; however, the solvent extraction procedure differs in the number of sonication steps, sample mass and solvent used. A flow chart of the soil extraction procedure is shown in Figure 4. Soil masses of approximately 2 g and a sample to solvent ratio of 1:5 (g/mL) are used for soil extraction. The extraction is carried out in a sonication bath chilled below 20 ⁰C and is a two-part extraction, first extracting in MeOH (6 hours) followed by a second sonication in 1:1 MeOH:H<sub><small>2</small></sub>O solution (14 hours). The extracts are centrifuged, and the supernatant is filtered through a 0.45 μm PTFE disk filter.  
  
===Detailed Risk Assessment===
+
The solvent volume should generally be 10 mL but if different soil masses are required, solvent volume should be 5 mL/g. The extraction results in 2 separate extracts (MeOH and MeOH:H<sub><small>2</small></sub>O) that are combined prior to analysis.
Detailed sediment risk assessment is conducted when SLRA results indicate one or more sediment contaminants exceed background conditions or regulatory threshold limits. For some contaminants, such as the dioxins and other persistent, bioaccumulative, and toxic substances (PBTs), technical guidance may mandate further examination, regardless of whether threshold levels are exceeded<ref name="Solomon2013">Solomon, K., Matthies, M., and Vighi, M., 2013. Assessment of PBTs in the European Union: a critical assessment of the proposed evaluation scheme with reference to plant protection products. Environmental Sciences Europe, 25(1), pp. 1-17.  [https://doi.org/10.1186/2190-4715-25-10 DOI: 10.1186/2190-4715-25-10]&nbsp;&nbsp; [https://enveurope.springeropen.com/articles/10.1186/2190-4715-25-10 Open Access Article]</ref><ref name="Matthies2016">Matthies, M., Solomon, K., Vighi, M., Gilman, A. and Tarazona, J.V., 2016. The origin and evolution of assessment criteria for persistent, bioaccumulative and toxic (PBT) chemicals and persistent organic pollutants (POPs). Environmental Science: Processes and Impacts, 18(9), pp. 1114-1128.  [https://doi.org/10.1039/C6EM00311G DOI: 10.1039/C6EM00311G]</ref>. Detailed sediment risk assessment typically follows a three-step framework similar to that described for ecological risk assessment - problem formulation, exposure analysis, and risk characterization<ref name="Suter2008">Suter, G.W., 2008. Ecological Risk Assessment in the United States Environmental Protection Agency: A Historical Overview. Integrated Environmental Assessment And Management, 4(3), pp. 285-289.  [https://doi.org/10.1897/IEAM_2007-062.1 DOI: 10.1897/IEAM_2007-062.1]&nbsp;&nbsp; Free download from: [https://bioone.org/journals/integrated-environmental-assessment-and-management/volume-4/issue-3/IEAM_2007-062.1/Ecological-Risk-Assessment-in-the-United-States-Environmental-Protection-Agency/10.1897/IEAM_2007-062.1.pdf?casa_token=ieq3Cnc-YdIAAAAA:_MH-gpnwpJKvZSV2Qew43Y4ocdgADq1HvugpvmrblcGONMJgvIjYB52zQnXn_oAUW0gTy5GAkfY BioOne]</ref>.
 
  
US sediment management guidance describes a detailed risk assessment process similar to that followed for US ecological risk assessment<ref name="USEPA2005"/>. The first step is problem formulation. It involves defining chemical and physical conditions, delineating the spatial footprint of the sediment area to be examined, and identifying the human uses and ecological features of the sediment. Historical data are included in this initial step to better understand the results of biota, sediment, and water sampling as well as laboratory toxicity testing results. The SLRA is often included as a part of problem formulation.
+
===Tissues===
  
The second step is exposure analysis. This step includes the identification of pathways by which human and aquatic organisms might directly or indirectly contact contaminants in the sediment. The exposure route (i.e., ingestion, dermal, or inhalation of particulates or gaseous emissions) and both the frequency and duration of contact (i.e., hourly, daily, or seasonally) are determined for each contaminant exposure pathway and human and ecological receptor. The environmental fate of the contaminant, factors affecting uptake, and the overall exposure dose are included in the calculation of the level of contaminant exposure. The exposure analysis also includes an effects assessment, whereby the biological response and associated level required to manifest different biological responses are determined for each contaminant.
+
Tissue matrices are extracted by 18-hour sonication using a ratio of 1 gram of wet tissue per 5 mL of MeOH. This extraction is performed in a sonication bath chilled below 20 ⁰C and the supernatant (MeOH) is filtered through a 0.45 μm PTFE disk filter.  
  
The third step is risk-characterization. It involves calculating the risks for each human and ecological receptor posed by each sediment contaminant, as well as the cumulative risk associated with the combined exposure to all contaminants exerting similar biological effects. An uncertainty analysis is often included in this step of the risk assessment to convey where knowledge or data are lacking regarding the presence of the contaminant in the sediment, the biological response associated with exposure to the contaminant, or the behavior of the receptor with respect to contact with the sediment. A sensitivity analysis also may be conducted to convey the range of exposures (lowest, typical, and worst-case) and risks associated with changes in key assumptions and parameter values used in the exposure calculations and effects assessment.
+
Due to the complexity of tissue matrices, an additional tissue cleanup step, adapted from prior research, can be used to reduce interferences<ref name="RussellEtAl2014">Russell, A.L., Seiter, J.M., Coleman, J.G., Winstead, B., Bednar, A.J., 2014. Analysis of munitions constituents in IMX formulations by HPLC and HPLC-MS. Talanta, 128, pp. 524–530. [https://doi.org/10.1016/j.talanta.2014.02.013 doi: 10.1016/j.talanta.2014.02.013]</ref><ref name="CrouchEtAl2020"/>. The cleanup procedure uses small scale chromatography columns prepared by loading 5 ¾” borosilicate pipettes with 0.2 g activated silica gel (100–200 mesh). The columns are wetted with 1 mL MeOH, which is allowed to fully elute and then discarded prior to loading with 1 mL of extract and collecting in a new amber vial. After the extract is loaded, a 1 mL aliquot of MeOH followed by a 1 mL aliquot of 2% HCL/MeOH is added. This results in a 3 mL silica treated tissue extract. This extract is vortexed and diluted to a final solvent ratio of 1:1 MeOH/H<sub><small>2</small></sub>O before analysis.
 
 
==Key Considerations==
 
===Stakeholder Engagement===
 
Stakeholder involvement is widely acknowledged as an important element of [[Wikipedia: Dredging | dredged]] material management<ref name="Collier2014">Collier, Z.A., Bates, M.E., Wood, M.D. and Linkov, I., 2014. Stakeholder engagement in dredged material management decisions. Science of the Total Environment, 496, pp. 248-256. [https://doi.org/10.1016/j.scitotenv.2014.07.044 DOI: 10.1016/j.scitotenv.2014.07.044]  Free download from: [https://www.researchgate.net/profile/Matthew-Bates-9/publication/264460412_Stakeholder_Engagement_in_Dredged_Material_Management_Decisions/links/5a9d50fbaca2721e3f32adea/Stakeholder-Engagement-in-Dredged-Material-Management-Decisions.pdf ResearchGate]</ref>, sediment remediation<ref name="Oen2010">Oen, A.M.P., Sparrevik, M., Barton, D.N., Nagothu, U.S., Ellen, G.J., Breedveld, G.D., Skei, J. and Slob, A., 2010. Sediment and society: an approach for assessing management of contaminated sediments and stakeholder involvement in Norway. Journal of Soils and Sediments, 10(2), pp. 202-208.  [https://doi.org/10.1007/s11368-009-0182-x DOI: 10.1007/s11368-009-0182-x]</ref>, and other environmental and sediment related activities<ref name="Gerrits2004">Gerrits, L. and Edelenbos, J., 2004. Management of Sediments Through Stakeholder Involvement. Journal of Soils and Sediments, 4(4), pp. 239-246.  [https://doi.org/10.1007/BF02991120 DOI: 10.1007/BF02991120]</ref><ref name="Braun2019">Braun, A.B., da Silva Trentin, A.W., Visentin, C. and Thomé, A., 2019. Sustainable remediation through the risk management perspective and stakeholder involvement: A systematic and bibliometric view of the literature. Environmental Pollution, 255(1), p.113221.  [https://doi.org/10.1016/j.envpol.2019.113221 DOI: 10.1016/j.envpol.2019.113221]</ref>.
 
  
Sediment management, particularly at the river basin scale, involves a wide variety of different environmental, governmental, and societal issues<ref name="Liu2018">Liu, C., Walling, D.E. and He, Y., 2018. The International Sediment Initiative case studies of sediment problems in river basins and their management. International Journal of Sediment Research, 33(2), pp. 216-219. [https://doi.org/10.1016/j.ijsrc.2017.05.005 DOI: 10.1016/j.ijsrc.2017.05.005]  Free download from: [https://www.researchgate.net/profile/Cheng-Liu-43/publication/317032034_Review_The_International_Sediment_Initiative_Case_Studies_of_sediment_problems_in_river_basins_and_their_management/links/5f4f37d2299bf13a319703df/Review-The-International-Sediment-Initiative-Case-Studies-of-sediment-problems-in-river-basins-and-their-management.pdf ResearchGate]</ref>. Incorporating these different views, interests, and perspectives into a form that builds consensus for whatever actions and goals are in mind (e.g., commercial ports and shipping, navigation, flood protection, or habitat restoration) necessitates a formal stakeholder engagement process<ref name="Slob2008">Slob, A.F.L., Ellen, G.J. and Gerrits, L., 2008. Sediment management and stakeholder involvement. In: Sustainable Management of Sediment Resources, Vol. 4: Sediment Management at the River Basin Scale, Owens, P.N. (ed.), pp. 199-216. Elsevier.  [https://doi.org/10.1016/S1872-1990(08)80009-8 DOI: 10.1016/S1872-1990(08)80009-8]</ref>.
+
==HPLC-UV and HPLC-MS Methods==
 +
{| class="wikitable mw-collapsible" style="float:left; margin-right:20px; text-align:center;"
 +
|+Table 3. Secondary HPLC-UV mobile phase gradient method concentrations
 +
|-
 +
| colspan="5" style="background-color:white;" | Method run time = 43 minutes; Column temperature = 25&deg;C<br>Injection volume = 50 &mu;L; Flow rate = 0.8 mL/min<br>Detector wavelengths = 210, 254, and 310 nm
 +
|-
 +
! Time<br>(min)
 +
! Reagent Water<br>(%)
 +
! MeOH<br>(%)
 +
! 0.1% TFA/Water<br>(%)
 +
! ACN<br>(%)
 +
|-
 +
| 0.00 || 75 || 10 || 10 || 5
 +
|-
 +
| 2.50 || 75 || 10 || 10 || 5
 +
|-
 +
| 2.60 || 39 || 46 ||10 || 5
 +
|-
 +
| 9.00 || 39 || 46 ||10 || 5
 +
|-
 +
| 9.10 || 33.5 || 51.5 || 10 || 5
 +
|-
 +
| 15.00 || 35 || 50 || 10 || 5
 +
|-
 +
| 15.10 || 43 || 42 || 10 || 5
 +
|-
 +
| 33.00 || 30 || 55 || 10 || 5
 +
|-
 +
| 33.10 || 75 || 10 || 10 || 5
 +
|-
 +
| 43.00 || 75 || 10 || 10 || 5
 +
|}
 +
{| class="wikitable mw-collapsible" style="float:right; margin-left:20px; text-align:center;"
 +
|+Table 4. Ionization source and detector parameters
 +
|-
 +
! Parameter
 +
! Value
 +
|-
 +
| Ionization Source || APCI
 +
|-
 +
| Ionization Mode || Negative
 +
|-
 +
| Drying Gas Temperature (&deg;C) || 350
 +
|-
 +
| Vaporizer Temperature (&deg;C) || 325
 +
|-
 +
| Drying Gas Flow (L/min) || 4.0
 +
|-
 +
| Nebulizer Pressure (psig) || 40
 +
|-
 +
| Corona Current (&mu;A) || 10
 +
|-
 +
| Capillary Potential (V) || 1500
 +
|-
 +
| Mass Range || 40 – 400
 +
|-
 +
| Fragmentor || 100
 +
|-
 +
| Gain || 1
 +
|-
 +
| Threshold || 0
 +
|-
 +
| Step Size || 0.20
 +
|-
 +
| Speed (&mu;/sec) || 743
 +
|-
 +
| Peak Width (min) || 0.06
 +
|-
 +
| Cycle Time (sec/cycle) || 0.57
 +
|}
  
Results from a three-year (2008-2010) [https://www.ngi.no/eng/Projects/Sediment-and-society Sediment and Society] research project funded by the Norwegian Research Council point to three important challenges that must be resolved for successful stakeholder engagement: (1) how to include people who have important management information and local knowledge, but not much influence in the decision-making process; (2) how to secure resources to ensure participation and (3) how to engage and motivate stakeholders to participate early in the sediment remediation planning process<ref name="Oen2010"/>.
+
The Primary HPLC-UV method uses a Phenomenex Synergi 4 µm Hydro-RP column (80Å, 250 x 4.6 mm), or comparable, and is based on both the HPLC method found in USEPA 8330B and previous work<ref name= "8330B"/><ref name="RussellEtAl2014"/><ref name="CrouchEtAl2020"/>. This separation relies on a reverse phase column and uses a gradient elution, shown in Table 2. Depending on the analyst’s needs and equipment availability, the method has been proven to work with either 0.1% TFA or 0.25% FA (vol/vol) mobile phase. Addition of a guard column like a Phenomenex SecurityGuard AQ C18 pre-column guard cartridge can be optionally used. These optional changes to the method have no impact on the method’s performance.  
  
===Conceptual Site Model===
+
The Secondary HPLC-UV method uses a Restek Pinnacle II Biphenyl 5 µm (150 x 4.6 mm) or comparable column and is intended as a confirmatory method. Like the Primary method, this method can use an optional guard column and utilizes a gradient elution, shown in Table 3.
The preparation of a conceptual site model (CSM) is a fundamental component of problem formulation and the first step in detailed sediment risk assessment. The CSM is a narrative and/or illustrative representation of the physical, chemical and biological processes that control the transport, migration and actual or potential impacts of sediment contamination to human and/or ecological receptors<ref name="NJDEP2019">New Jersey Department of Environmental Protection, 2019. Technical Guidance for Preparation and Submission of a Conceptual Site Model. Version 1.1. Site Remediation and Waste Management Program, Trenton, NJ. 46 pp. [https://www.nj.gov/dep/srp/guidance/srra/csm_tech_guidance.pdf Free download].</ref><ref name="USEPA2011">US Environmental Protection Agency, 2011. Guidance for the Development of Conceptual Models for a Problem Formulation Developed for Registration Review. Environmental Fate and Effects Division, Office of Pesticide Programs, Washington, D.C. [https://www.epa.gov/pesticide-science-and-assessing-pesticide-risks/guidance-development-conceptual-models-problem Website]</ref>. The CSM should include a “food web” because the aquatic food web is an important exposure pathway by which contaminants in the sediment reach humans and pelagic aquatic life<ref name="Arnot2004">Arnot, J.A. and Gobas, F.A., 2004. A Food Web Bioaccumulation Model for Organic Chemicals in Aquatic Ecosystems. Environmental Toxicology and Chemistry, 23(10), pp. 2343-2355.  [https://doi.org/10.1897/03-438 DOI: 10.1897/03-438]</ref>.
+
   
 
+
For instruments equipped with a mass spectrometer (MS), a secondary MS method is available and was developed alongside the Primary UV method. The method was designed for use with a single quadrupole MS equipped with an atmospheric pressure chemical ionization (APCI) source, such as an Agilent 6120B. A majority of the analytes shown in Table 1 are amenable to this MS method, however nitroglycerine (which is covered extensively in USEPA method 8332) and 2-,3-, and 4-nitrotoluene compounds aren’t compatible with the MS methodMS method parameters are shown in Table 4.
The CSM provides an early opportunity for critical examination of the interactions between sediment and the water column and the influence of groundwater inputs, surface runoff, and hydrodynamics. For example, there are situations where impacts in the aquatic food web can be driven by ongoing inputs to the water column from upstream sources, but mistakenly connected to polluted sediments. Other considerations included in a CSM can be socio-economic and include linkages to the ecosystem services provided by sediments<ref name="Broszeit2019">Broszeit, S., Beaumont, N.J., Hooper, T.L., Somerfield, P.J. and Austen, M.C., 2019. Developing conceptual models that link multiple ecosystem services to ecological research to aid management and policy, the UK marine example. Marine Pollution Bulletin, 141, pp.236-243.  [https://doi.org/10.1016/j.marpolbul.2019.02.051 DOI: 10.1016/j.marpolbul.2019.02.051]&nbsp;&nbsp; [https://www.sciencedirect.com/science/article/pii/S0025326X19301511/pdfft?md5=34993d6c3a57b6fb18a8b6329597fcb9&pid=1-s2.0-S0025326X19301511-main.pdf Open Access Article.]</ref><ref name="Wang2021">Wang, J., Lautz, L.S., Nolte, T.M., Posthuma, L., Koopman, K.R., Leuven, R.S. and Hendriks, A.J., 2021. Towards a systematic method for assessing the impact of chemical pollution on ecosystem services of water systems. Journal of Environmental Management, 281, p. 111873.  [https://doi.org/10.1016/j.jenvman.2020.111873 DOI: 10.1016/j.jenvman.2020.111873]&nbsp;&nbsp; [https://www.sciencedirect.com/science/article/pii/S0301479720317989/pdfft?md5=daff5e94f8aed44ffce6508afef2308c&pid=1-s2.0-S0301479720317989-main.pdf  Open Access Article.]</ref>, or the social, economic and environmental impacts of sediment management alternatives. In such a case, when risk assessment seeks to compare risks of various management actions (including no action), the CSM can be termed a sustainability CSM, or SustCSM<ref name="McNally2020">McNally, A.D., Fitzpatrick, A.G., Harrison, D., Busey, A., and Apitz, S.E., 2020. Tiered approach to sustainability analysis in sediment remediation decision making. Remediation Journal, 31(1), pp. 29-44.  [https://doi.org/10.1002/rem.21661 DOI: 10.1002/rem.21661]&nbsp;&nbsp; [https://onlinelibrary.wiley.com/doi/epdf/10.1002/rem.21661 Open Access Article].</ref><ref name="Holland2011">Holland, K.S., Lewis, R.E., Tipton, K., Karnis, S., Dona, C., Petrovskis, E., and Hook, C., 2011. Framework for Integrating Sustainability Into Remediation Projects. Remediation Journal, 21(3), pp. 7-38. [https://doi.org/10.1002/rem.20288 DOI: 10.1002/rem.20288].</ref>. At a minimum, however, the purpose of the CSM is to illustrate the scope of the risk assessment and guide the quantification of exposure and risk.
 
 
 
===Environmental Fate===
 
An important consideration in exposure analysis is the determination of the bioavailable fraction of the contaminant in the sediment. There are two considerations. First, the adverse condition may be buried deep enough in sediments to be below the biologically available zone; typically, conditions in sediment below a depth of 5 cm will not contact burrowing benthic organisms<ref name="Anderson2010">Anderson, R.H., Prues, A.G. and Kravitz, M.J., 2010. Determination of the biologically relevant sampling depth for terrestrial ecological risk assessments. Geoderma, 154(3-4), pp.336-339.  [https://doi.org/10.1016/j.geoderma.2009.11.004 DOI: 10.1016/j.geoderma.2009.11.004]</ref>. If there is no prospect for the adverse condition to come closer to the surface, then the risk assessment could conclude the risk of exposure is insignificant. The second consideration relates to chemistry and the factors involved in the binding to sediment particles or the chemical form of the substance in the sediment<ref name="Eggleton2004">Eggleton, J. and Thomas, K.V., 2004. A review of factors affecting the release and bioavailability of contaminants during sediment disturbance events. Environment International, 30(7), pp. 973-980.  [https://doi.org/10.1016/j.envint.2004.03.001 DOI: 10.1016/j.envint.2004.03.001]</ref>. However, these assumptions should be examined in the context of [[Climate Change Primer | climate change]], and the likelihood of more frequent and extreme events, putting burial at risk, higher temperatures and changing biogeochemical conditions, which may alter environmental fate of contaminants, compared to historical studies.  
 
 
 
The above contaminant bioavailability considerations are important factors influencing assumptions in the risk assessment about contaminant exposure<ref name="Peijnenburg2020">Peijnenburg, W.J., 2020. Implementation of bioavailability in prospective and retrospective risk assessment of chemicals in soils and sediments. In: The Handbook of Environmental Chemistry, vol 100, Bioavailability of Organic Chemicals in Soil and Sediment, Ortega-Calvo, J.J., Parsons, J.R. (ed.s), pp.391-422. Springer. [https://doi.org/10.1007/698_2020_516 DOI: 10.1007/698_2020_516]</ref><ref name="Ortega-Calvo2015">Ortega-Calvo, J.J., Harmsen, J., Parsons, J.R., Semple, K.T., Aitken, M.D., Ajao, C., Eadsforth, C., Galay-Burgos, M., Naidu, R., Oliver, R. and Peijnenburg, W.J., 2015. From Bioavailability Science to Regulation of Organic Chemicals. Environmental Science and Technology, 49, 10255−10264. [https://doi.org/10.1021/acs.est.5b02412 DOI: 10.1021/acs.est.5b02412]&nbsp;&nbsp; [https://pubs.acs.org/doi/pdf/10.1021/acs.est.5b02412 Open Access Article].</ref>. There have been recent advances in the use of sorbent amendments applied to contaminated sediments that alter sediment geochemistry, increase contaminant binding, and reduce contaminant exposure risks to people and the environment<ref name="Ghosh2011">Ghosh, U., Luthy, R.G., Cornelissen, G., Werner, D. and Menzie, C.A., 2011. In-situ sorbent amendments: a new direction in contaminated sediment management. Environmental Science and Technology, 45, 4, 1163–1168.  [https://doi.org/10.1021/es102694h DOI: 10.1021/es102694h]&nbsp;&nbsp; [https://pubs.acs.org/doi/pdf/10.1021/es102694h Open Access Article]</ref>. [[Passive Sampling of Sediments | Passive sampling techniques]] have emerged to quantify chemical binding to sediment and determine the freely dissolved concentration that is bioavailable.
 
 
 
===Assessment and Measurement Endpoints===
 
Assessment and measurement endpoints used in sediment risk assessment are comparable to those described in USEPA ecological risk assessment guidance<ref name="USEPA2005"/><ref name="USEPA1992">US Environmental Protection Agency (USEPA), 1992. Framework for Ecological Risk Assessment, EPA/630/R-92/001. Risk Assessment Forum, Washington DC.  [[Media: EPA-630-R-92-001.pdf | Report.pdf]]</ref><ref name="USEPA1996">US Environmental Protection Agency (USEPA), 1996. Eco Update: Ecological Significance and Selection of Candidate Assessment Endpoints. EPA/540/F-95/037. Office of Solid Waste and Emergency Response, Washington DC.  [[Media: EPA 540-F-95-037.pdf | Report.pdf]]</ref><ref name="USEPA1997b">US Environmental Protection Agency (USEPA), 1997. Ecological Risk Assessment Guidance for Superfund: Process for Designing and Conducting Ecological Risk Assessments - Interim Final, EPA 540/R-97/006. Office of Solid Waste and Emergency Response, Washington DC.  [[Media: EPA 540-R-97-006.pdf | Report.pdf]]</ref><ref name="USEPA1998">US Environmental Protection Agency (USEPA), 1998. Guidelines for Ecological Risk Assessment. EPA/630/R-95/002F. Risk Assessment Forum, Washington DC.  [[Media: EPA 630-R-95-002F.pdf | Report.pdf]]</ref>. A sediment risk assessment, and ecological risk assessments more broadly, must have clearly defined endpoints that are socially and biologically relevant, accessible to prediction and measurement, and susceptible to the hazard being assessed<ref name="USEPA1992"/>.
 
 
 
Assessment endpoints for humans include both carcinogenic and noncarcinogenic effects. Due to their assumed higher levels of exposure, human receptors used in sediment risk assessment typically include recreational, commercial, and subsistence fishermen, i.e., people who might be at increased risk from eating fish or contacting the sediment or water on a regular basis such as indigenous peoples, immigrants from fishing cultures, and subsistence fishers who rely upon fish as a major source of protein. Special considerations are given to women of child-bearing age, pregnant women and young children. Assessment endpoints for ecological receptors focus on benthic organisms, resident fish, piscivorous and other predatory birds and marine mammals. Endpoints typically include mortality, reproductive success and population susceptibility to disease or similar adverse chronic conditions.
 
 
 
Measurement endpoints are related quantitatively to each assessment endpoint. Whenever practical, multiple measurement endpoints are chosen to provide additional lines of evidence for each assessment endpoint. For example, for humans, it might be possible to measure contaminant levels in both food items and human blood or tissue. For predatory fish, birds and mammals, it might be possible to measure contaminants in both prey and predator tissues. Measurement endpoints can be selected to assess non-chemical stressors as well, such as habitat alteration and water turbidity. Typically, measurement endpoints are compared to measurements at a reference site to ascertain the degree of departure from local natural or background conditions.
 
 
 
===Sediment Toxicity Testing===
 
Sediment bioassays are an integral part of effects characterization when assessing the risks posed by contaminated sediments and developing sediment quality guidelines<ref name="USEPA2014">US Environmental Protection Agency (USEPA), 2014. Toxicity Testing and Ecological Risk Assessment Guidance for Benthic Invertebrates. Office of Chemical Safety and Pollution Prevention, Washington DC.  [https://www.epa.gov/pesticide-science-and-assessing-pesticide-risks/toxicity-testing-and-ecological-risk-assessment Website]&nbsp;&nbsp; [[Media: USEPA2014.pdf | Report.pdf]]</ref><ref name="Simpson2016a">Simpson, S., Campana, O., Ho, K., 2016. Chapter 7, Sediment Toxicity Testing. In: J. Blasco, P.M. Chapman, O. Campana, M. Hampel (ed.s), Marine Ecotoxicology: Current Knowledge and Future Issues. Academic Press Incorporated. pp. 199-237.  [https://doi.org/10.1016/B978-0-12-803371-5.00007-2 DOI: 10.1016/B978-0-12-803371-5.00007-2]</ref>. The selection of appropriate sediment bioassays is dependent on the questions being addressed, the physical and chemical characteristics of the sediment matrix, the nature of the contaminant(s) of concern, and preferences of the supervising regulatory authority for the test method and test organisms<ref name="Amiard-Triquet2015">Amiard-Triquet, C., Amiard, J.C. and Mouneyrac, C. (ed.s), 2015. Aquatic Ecotoxicology: Advancing Tools For Dealing With Emerging Risks. Academic Press, NY. ISBN #9780128009499.  [https://doi.org/10.1016/B978-0-12-800949-9.12001-7 DOI: 10.1016/B978-0-12-800949-9.12001-7]</ref>. Bioassay procedures have been standardized in several countries, and it is not unusual for different test methods to be required in different countries for the same sediment management purpose<ref name="DelValls2004">DelValls, T.A., Andres, A., Belzunce, M.J., Buceta, J.L., Casado-Martinez, M.C., Castro, R., Riba, I., Viguri, J.R. and Blasco, J., 2004. Chemical and ecotoxicological guidelines for managing disposal of dredged material. TrAC Trends in Analytical Chemistry, 23(10-11), pp. 819-828.  [https://doi.org/10.1016/j.trac.2004.07.014 DOI: 10.1016/j.trac.2004.07.014]&nbsp;&nbsp; Free download from: [https://d1wqtxts1xzle7.cloudfront.net/46085251/Chemical_and_Ecotoxicological_Guidelines20160530-23122-4fooj2-with-cover-page-v2.pdf?Expires=1637618385&Signature=aNsOfciO0HPhucL8S713nenRlvviD2dbLi8y63n93iGX~Cc7CHwyYQ2bfNlT6VnjuFJeVT83M01Xog6esr14gyvL9pmlo3hw5fQp5J9vA8gqXcT9kQfM1T2Q0Ig883yGMFmtgUrrU6p8c8V~8rh5DTKDD5ZsiL4zloGgF6Gs4F2ecEDqyFBZ17yYpXGVVBmpfm87sUpaPY0Ix9iWJ~5nxM~HF6XYl1sA1rgFSerT-Y5W8Ma7-XMljnYHQ7hW7eqMjyN66IDj7pwafG7Ox-Hnp07IuD-oMY1dHHrzTOmHpXpWgMYLn2zf1BSmy~tqIFHE6UjZn5ako93PgExuzEjEiw__&Key-Pair-Id=APKAJLOHF5GGSLRBV4ZA Academia.edu]</ref>. Guidance documents in Australia, Canada, Europe and the US cover the wide range of sediment bioassay procedures most often used in risk assessment<ref name="Bat2005">Bat, L., 2005. A Review of Sediment Toxicity Bioassays Using the Amphipods and Polychaetes. Turkish Journal of Fisheries and Aquatic Sciences, 5(2), pp. 119-139.  [https://dergipark.org.tr/en/pub/trjfas-ayrildi/issue/13287/160604 Free download]&nbsp;&nbsp; [[Media: Bat2005.pdf | Report.pdf]]</ref><ref name="Keddy1995">Keddy, C.J., Greene, J.C. and Bonnell, M.A., 1995. Review of Whole-Organism Bioassays: Soil, Freshwater Sediment, and Freshwater Assessment in Canada. Ecotoxicology and Environmental Safety, 30(3), pp. 221-251.  [https://doi.org/10.1006/eesa.1995.1027 DOI: 10.1006/eesa.1995.1027]</ref><ref name="Giesy1990">Giesy, J.P., Rosiu, C.J., Graney, R.L. and Henry, M.G., 1990. Benthic invertebrate bioassays with toxic sediment and pore water. Environmental Toxicology and Chemistry, 9(2), pp. 233-248.  [https://doi.org/10.1002/etc.5620090214 DOI: 10.1002/etc.5620090214]</ref><ref name="Simpson2016b">Simpson, S. and Batley, G. (ed.s), 2016. Sediment Quality Assessment: A Practical Guide, Second Edition. 358 pp. CSIRO Publishing, Australia. ISBN # 9781486303847.</ref><ref name="Moore2019">Moore, D.W., Farrar, D., Altman, S. and Bridges, T.S., 2019. Comparison of Acute and Chronic Toxicity Laboratory Bioassay Endpoints with Benthic Community Responses in Field‐Exposed Contaminated Sediments. Environmental Toxicology and Chemistry, 38(8), pp. 1784-1802.  [https://doi.org/10.1002/etc.4454 DOI: 10.1002/etc.4454]</ref>.
 
 
 
In general, sediment toxicity tests focus on either (acute) lethality in whole organisms (typically benthic infaunal species such as amphipods and polychaetes) following short-term or acute exposures (<14 days) or (chronic) sublethal responses (e.g., reduced growth or reproduction or both) following longer-term exposures<ref name="Simpson2016a"/>. It is not unusual in sediment risk assessment to rely on more than one sediment bioassay. Both acute and chronic tests involving either solid-phase or pore-water sediment fractions can be useful to discern the contributions of different contaminants in whole sediment by examining the response of different endpoints in different test organisms<ref name="Keddy1995"/><ref name="Giesy1990"/>. The application of more specialized techniques such as toxicity identification evaluations (TIEs) have also proved useful to help identify contaminants or contaminant classes most likely responsible for toxicity and to exclude potentially confounding factors such as ammonia<ref name="Ho2013">Ho, K.T. and Burgess, R.M., 2013. What's causing toxicity in sediments? Results of 20 years of toxicity identification and evaluations. Environmental Toxicology and Chemistry, 32(11), pp. 2424-2432.  [https://doi.org/10.1002/etc.2359 DOI: 10.1002/etc.2359]</ref><ref name="Bailey2016">Bailey, H.C., Curran, C.A., Arth, P., Lo, B.P. and Gossett, R., 2016. Application of sediment toxicity identification evaluation techniques to a site with multiple contaminants. Environmental Toxicology and Chemistry, 35(10), pp. 2456-2465.  [https://doi.org/10.1002/etc.3488 DOI: 10.1002/etc.3488]</ref>.
 
 
 
===Uncertainty===
 
As part of the overall analysis of risk from exposure to certain sediment conditions, it is generally understood there is a moderate degree of uncertainty associated with sampling and the environmental fate of contaminants; an order of magnitude of uncertainty associated with ecological exposure and dose-response; and greater than an order of magnitude of uncertainty associated with the quantification of potential human health effects<ref name="DiGuardo2018">Di Guardo, A., Gouin, T., MacLeod, M. and Scheringer, M., 2018. Environmental fate and exposure models: advances and challenges in 21st century chemical risk assessment. Environmental Science: Processes and Impacts, 20(1), pp. 58-71.  [https://doi.org/10.1039/C7EM00568G DOI: 10.1039/C7EM00568G]&nbsp;&nbsp;  [https://pubs.rsc.org/en/content/articlehtml/2018/em/c7em00568g  Open access article]</ref>. The sources of uncertainty and significance to sediment risk assessment can vary widely, thereby affecting confidence in the decisions made based on risk assessment<ref name="Reckhow1994">Reckhow, K.H., 1994. Water quality simulation modeling and uncertainty analysis for risk assessment and decision making. Ecological Modelling, 72(1-2), pp.1-20.  [https://doi.org/10.1016/0304-3800(94)90143-0 DOI: 10.1016/0304-3800(94)90143-0]</ref><ref name="Chapman2002">Chapman, P.M., Ho, K.T., Munns Jr, W.R., Solomon, K. and Weinstein, M.P., 2002. Issues in sediment toxicity and ecological risk assessment. Marine Pollution Bulletin, 44(4), pp. 271-278.  [https://doi.org/10.1016/S0025-326X(01)00329-0 DOI: 10.1016/S0025-326X(01)00329-0]</ref>.
 
 
 
Consequently, technical guidance in several countries encourages including a quantitative uncertainty analysis in sediment risk assessment<ref name="USEPA2005"/><ref name="Tarazona2014"/><ref name="Apitz2005a"/><ref name="Apitz2005b"/>. The aim of uncertainty analysis is to express either quantitatively or qualitatively the limitations inherent in predicting exposures and effects and, ultimately, the level of overall risk posed by sediment conditions<ref name="Batley2002">Batley, G.E., Burton, G.A., Chapman, P.M. and Forbes, V.E., 2002. Uncertainties in Sediment Quality Weight-of-Evidence (WOE) Assessments. Human and Ecological Risk Assessment, 8(7), pp. 1517-1547.  [https://doi.org/10.1080/20028091057466 DOI: 10.1080/20028091057466]</ref>. Sediment risk assessment increasingly relies on a weight-of-evidence process to improve the certainty of conclusions about whether or not impairment exists due to sediment contamination, and, if so, which stressors and biological species (or ecological responses) are of greatest concern<ref name="Burton2002">Burton, G.A., Batley, G.E., Chapman, P.M., Forbes, V.E., Smith, E.P., Reynoldson, T., Schlekat, C.E., Besten, P.J.D., Bailer, A.J., Green, A.S. and Dwyer, R.L., 2002. A Weight-of-Evidence Framework for Assessing Sediment (or Other) Contamination: Improving Certainty in the Decision-Making Process. Human and Ecological Risk Assessment, 8(7), pp. 1675-1696.  [https://doi.org/10.1080/20028091056854 DOI: 10.1080/20028091056854]</ref>. Recent advancements, including the use of Bayesian networks and geographic information systems, also help capture the range of variability in both measured and predicted exposures and responses<ref name="Holsman2017">Holsman, K., Samhouri, J., Cook, G., Hazen, E., Olsen, E., Dillard, M., Kasperski, S., Gaichas, S., Kelble, C.R., Fogarty, M. and Andrews, K., 2017. An ecosystem‐based approach to marine risk assessment. Ecosystem Health and Sustainability, 3(1), p. e01256.  [https://doi.org/10.1002/ehs2.1256 DOI: 10.1002/ehs2.1256]&nbsp;&nbsp; [https://www.tandfonline.com/doi/full/10.1002/ehs2.1256 Open access article]</ref><ref name="Marcot2019">Marcot, B.G. and Penman, T.D., 2019. Advances in Bayesian network modelling: Integration of modelling technologies. Environmental Modelling and Software, 111, pp. 386-393.  [https://doi.org/10.1016/j.envsoft.2018.09.016 DOI: 10.1016/j.envsoft.2018.09.016]</ref><ref name="Men2019">Men, C., Liu, R., Wang, Q., Guo, L., Miao, Y. and Shen, Z., 2019. Uncertainty analysis in source apportionment of heavy metals in road dust based on positive matrix factorization model and geographic information system. Science of The Total Environment, 652, pp. 27-39.  [https://doi.org/10.1016/j.scitotenv.2018.10.212 DOI: 10.1016/j.scitotenv.2018.10.212]</ref>. The level of sophistication applied to the uncertainty analysis is a subjective consideration and often decided by regulatory pressures, public perceptions and the likely cost (not only economic, but also social and environmental) of mitigating or removing the contamination.
 
 
 
==Role in Sediment Management==
 
Whether or not remediation of contaminated sediments is warranted depends on the magnitude of direct or indirect health risks to humans, ecological threats to aquatic biota, and the extent of risk reduction that can be achieved by removal or containment of the contamination<ref name="Kvasnicka2020">Kvasnicka, J., Burton Jr, G.A., Semrau, J. and Jolliet, O., 2020. Dredging Contaminated Sediments: Is it Worth the Risks? Environmental Toxicology and Chemistry, 39(3), pp. 515-516.  [https://setac.onlinelibrary.wiley.com/doi/pdfdirect/10.1002/etc.4679 DOI: 10.1002/etc.4679]&nbsp;&nbsp; [https://setac.onlinelibrary.wiley.com/doi/pdfdirect/10.1002/etc.4679 Open access article]</ref>. As all sediment management also introduces risk pathways, such as sediment re-suspension leading to contaminant release, possible impacts due to land, water and energy usage, and risk to workers, remedial decision-making should also consider the risks posed by the remedial process. There are two types of remediation risks inherent in sediment remediation - engineering and biological. Sediment remedy implementation risks are predominantly short-term engineering issues associated with applying the remedy such as worker and community health and safety, equipment failures, and accident rates<ref name="Wenning2006">Wenning, R.J., Sorensen, M. and Magar, V.S., 2006. Importance of Implementation and Residual Risk Analyses in Sediment Remediation. Integrated Environmental Assessment and Management, 2(1), pp. 59-65.  [https://doi.org/10.1002/ieam.5630020111 DOI: 10.1002/ieam.5630020111]&nbsp;&nbsp; [https://setac.onlinelibrary.wiley.com/doi/full/10.1002/ieam.5630020111 Open access article]</ref>. Sediment residual risks are predominantly longer-term changes in exposure and effects to humans, aquatic biota, and wildlife after the remedy has been implemented<ref name="Wenning2006"/>.
 
 
 
In addition to evaluating sediment conditions prior to remediation, sediment risk assessment can be useful to understand how the engineering risks, the contaminant exposure pathways, and which human and wildlife populations are at risk might change with different remediation options<ref name="NRC2001">National Research Council (NRC), 2001. A Risk‐Management Strategy For PCB Contaminated Sediments. Committee On Remediation Of PCB‐Contaminated Sediments, Board On Environmental Studies And Toxicology. National Academies Press, Washington DC. 452 pp. ISBN: 0-309-58873-1 [https://doi.org/10.17226/10041 DOI: 10.17226/10041]&nbsp;&nbsp; Free download from: [https://www.nap.edu/catalog/10041/a-risk-management-strategy-for-pcb-contaminated-sediments The National Academies Press]</ref>. Decision tools such as multi-criteria decision analysis (MCDA), or sustainability assessment<ref name="Apitz2018">Apitz, S.E., Fitzpatrick, A., McNally, A., Harrison, D., Coughlin, C., and Edwards, D.A., 2018. Stakeholder Value-Linked Sustainability Assessment: Evaluating Remedial Alternatives for the Portland Harbor Superfund Site, Portland, Oregon, USA. Integrated Environmental Assessment and Management, 14(1), pp. 43-62. [https://doi.org/10.1002/ieam.1998 DOI: 10.1002/ieam.1998]&nbsp;&nbsp; [https://setac.onlinelibrary.wiley.com/doi/full/10.1002/ieam.1998 Open access article]</ref><ref name="Fitzpatrick2018">Fitzpatrick, A., Apitz, S.E., Harrison, D., Ruffle, B., and Edwards, D.A., 2018. The Portland Harbor Superfund Site Sustainability Project:  Introduction. Integrated Environmental Assessment and Management, 14(1), pp. 17-21.  [https://doi.org/10.1002/ieam.1997 DOI: 10.1002/ieam.197]&nbsp;&nbsp; [https://setac.onlinelibrary.wiley.com/doi/full/10.1002/ieam.1997 Open access article]</ref>, for example, incorporate elements from sediment risk assessment to support remediation decision making<ref name="Linkov2006a">Linkov, I., Satterstrom, F.K., Kiker, G., Seager, T.P., Bridges, T., Gardner, K.H., Rogers, S.H., Belluck, D.A. and Meyer, A., 2006. Multicriteria Decision Analysis: A Comprehensive Decision Approach for Management of Contaminated Sediments. Risk Analysis, 26(1), pp. 61-78.  [https://doi.org/10.1111/j.1539-6924.2006.00713.x DOI: 10.1111/j.1539-6924.2006.00713.x]&nbsp;&nbsp; Free download from: [https://digitalcommons.unl.edu/cgi/viewcontent.cgi?article=1164&context=usarmyceomaha US Army Corps of Engineers]</ref>. Sediment risk assessment also plays an important role in the implementation of monitored natural recovery (MNR) as a remediation strategy<ref name="Magar2006">Magar, V.S. and Wenning, R.J., 2006. The role of monitored natural recovery in sediment remediation. Integrated Environmental Assessment and Management, 2(1), pp. 66-74.  [https://doi.org/10.1002/ieam.5630020112 DOI: 10.1002/ieam.5630020112]&nbsp;&nbsp; [https://setac.onlinelibrary.wiley.com/doi/full/10.1002/ieam.5630020112 Open access article]</ref>. Insofar as ecological recovery is affected by surface‐sediment‐contaminant concentrations, the primary recovery processes for MNR are natural sediment burial and transformation of the contaminant to less toxic forms by biological or chemical processes<ref name="Magar2009">Magar, V.S., Chadwick, D.B., Bridges, T.S., Fuchsman, P.C., Conder, J.M., Dekker, T.J., Steevens, J.A., Gustavson, K.E. and Mills, M.A., 2009. Technical Guide: Monitored Natural Recovery at Contaminated Sediment Sites. Environmental Security Technology Certification Program (ESTCP) Project ER-0622. 277 pp.  [https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Sediments/In-place-Remediation/ER-200622/(language)/eng-US Website]&nbsp;&nbsp; [https://apps.dtic.mil/sti/pdfs/ADA512822.pdf Free download]</ref>.
 
 
 
Since risk reduction is the long‐term goal of contaminated sediment management<ref name="Apitz2002">Apitz, S.E. and Power, E.A., 2002. From Risk Assessment to Sediment Management: An International Perspective. Journal of Soils and Sediments, 2(2), pp. 61-66.  [https://doi.org/10.1007/BF02987872 DOI: 10.1007/BF02987872]&nbsp;&nbsp; Free download from: [https://www.researchgate.net/profile/Sabine-Apitz/publication/225649107_From_risk_assessment_to_sediment_management_An_international_perspective/links/09e4150cb2df7c6331000000/From-risk-assessment-to-sediment-management-An-international-perspective.pdf ResearchGate]</ref>, predicting the rate at which contaminant exposures and risks are mitigated by sedimentation and degradation over time can be aided by including parameters in the risk assessment that calculate the rate of contaminant removal or decay in the sediment. Evaluating sediment management options in terms of risk reduction involves assessing risks under the diverse set of conditions that include the current state of the site as well as the conditions that would occur both during the implementation work and long after the work is complete and the ecosystem stabilizes<ref name="Linkov2006b">Linkov, I., Satterstrom, F.K., Kiker, G.A., Bridges, T.S., Benjamin, S.L. and Belluck, D.A., 2006. From Optimization to Adaptation: Shifting Paradigms in Environmental Management and Their Application to Remedial Decisions. Integrated Environmental Assessment and Management, 2(1), pp. 92-98.  [https://doi.org/10.1002/ieam.5630020116 DOI: 10.1002/ieam.5630020116]&nbsp;&nbsp; [https://setac.onlinelibrary.wiley.com/doi/epdf/10.1002/ieam.5630020116 Open access article]</ref><ref name="Reible2003">Reible, D., Hayes, D., Lue-Hing, C., Patterson, J., Bhowmik, N., Johnson, M. and Teal, J., 2003. Comparison of the Long-Term Risks of Removal and In Situ Management of Contaminated Sediments in the Fox River. Soil and Sediment Contamination, 12(3), pp. 325-344[https://doi.org/10.1080/713610975 DOI: 10.1080/713610975]</ref>.
 
  
 
==Summary==
 
==Summary==
Effective sediment risk assessment begins with an initial scoping and planning exercise. The work proceeds to a SLRA and, if warranted, detailed risk assessment using a process comparable to ecological risk assessment. The key elements of sediment risk assessment must include a well‐designed and site‐specific CSM; a transparent and well‐thought‐out biological and chemical data collection and analysis plan; carefully selected reference sites and decision criteria; and an explicit discussion of uncertainty. If the risk assessment concludes that unacceptable risks exist, risk‐management strategies must be evaluated, selected, implemented, and their success evaluated.
+
The extraction methods and instrumental methods in this article build upon prior munitions analytical methods by adding new compounds, combining legacy and insensitive munitions analysis, and expanding usable sample matrices. These methods have been verified through extensive round robin testing and validation, and while the methods are somewhat challenging, they are crucial when simultaneous analysis of both insensitive and legacy munitions is needed.  
 
 
Sediment risk assessments are designed to simulate and predict plausible interactions between contaminants or other stressors and both ecological and human receptors. The intent is to derive meaningful insights that provide conclusions that are both rational and protective, in that they err on the side of over-estimating the likely environmental risks. Although conservative assumptions should always be used early in the sediment risk assessment process, final decisions should be supported by refined, realistic estimates of risk provided by site‐specific data and sound analytical approaches. It is increasingly evident after nearly 50 years of application that sediment risk assessment is most useful when supported by a well‐designed, site‐specific, and tiered assessment process<ref name="Bridges2005">Bridges, T., Berry, W., Della Sala, S., Dorn, P., Ells, S., Gries, T., Ireland, S., Maher, E., Menzie, C., Porebski, L., and Stronkhorst, J., 2005. Chapter 6: A framework for assessing and managing risks from contaminated sediments. In: Use of sediment quality guidelines and related tools for the assessment of contaminated sediments. Wenning, Batley, Ingersoll, and Moore, editors. Society of Environmental Toxicology and Chemistry (SETAC), pp. 227–266. ISBN: 1-880611-71-6</ref>.
 
  
 
==References==
 
==References==
Line 101: Line 228:
  
 
==See Also==
 
==See Also==
 +
*[[Media: ERDC_TR-21-12.pdf | Preparative, Extraction, and Analytical Methods for Simultaneous Determination of Legacy and Insensitive Munition (IM) Constituents in Aqueous, Soil or Sediment, and Tissue Matrices]]
 +
*[https://serdp-estcp.mil/focusareas/9f7a342a-1b13-4ce5-bda0-d7693cf2b82d/uxo#subtopics  SERDP/ESTCP Focus Areas – UXO – Munitions Constituents]
 +
*[https://denix.osd.mil/edqw/home/  Environmental Data Quality Workgroup]

Latest revision as of 19:23, 29 July 2024

Munitions Constituents – Sample Extraction and Analytical Techniques

Munitions Constituents, including insensitive munitions (IM), are a broad category of compounds which, in areas where manufactured or used, can be found in a variety of environmental matrices (waters, soil, and tissues). This presents an analytical challenge when a variety of these munitions are to be quantified. This article discusses sample extraction methods for each typical sample matrix (high level water, low level water, soil and tissue) as well as the accompanying HPLC-UV analytical method for 27 compounds of interest (legacy munitions, insensitive munitions, and surrogates).

Related Article(s):

Contributor(s):

  • Dr. Austin Scircle

Key Resource(s):

  • Methods for simultaneous quantification of legacy and insensitive munition (IM) constituents in aqueous, soil/sediment, and tissue matrices[2]

Introduction

Table 1. Analyte list with acronyms and CAS numbers.
Compound Acronym CAS Number
1,2-Dinitrobenzene (surrogate) 1,2-DNB (surr.) 528-29-0
1,3-Dinitrobenzene 1,3-DNB 99-65-0
1,3,5-Trinitrobenzene 1,3,5-TNB 99-35-4
1,4-Dinitrobenzene 1,4-DNB (surr.) 100-25-4
2-Amino-4,6-dinitrotoluene 2-Am-4,6-DNT 35572-78-2
2-Nitrophenol 2-NP 88-75-5
2-Nitrotoluene 2-NT 88-72-2
2,4-Dinitrophenol 2,4-DNP 51-28-5
2,4-Dinitrotoluene 2,4-DNT 121-14-2
2,4,6-Trinitrophenol Picric Acid (PA) 88-89-1
2,4,6-Trinitrotoluene 2,4,6-TNT 118-96-7
2,6-Dinitrotoluene 2,6-DNT 606-20-2
3-Nitrotoluene 3-NT 99-08-1
3,5-Dinitroaniline 3,5-DNA 618-87-1
4-Amino-2,6-dinitrotoluene 4-Am-2,6-DNT 19406-51-0
4-Nitrophenol 4-NP 100-02-7
4-Nitrotoluene 4-NT 99-99-0
2,4-Dinitroanisole DNAN 119-27-7
Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine HMX 2691-41-0
Nitrobenzene NB 98-95-3
Nitroglycerine NG 55-63-0
Nitroguanidine NQ 556-88-7
3-Nitro-1,2,4-triazol-5-one NTO 932-64-9
ortho-Nitrobenzoic acid o-NBA (surr.) 552-16-9
Pentaerythritol tetranitrate PETN 78-11-5
Hexahydro-1,3,5-trinitro-1,3,5-triazine RDX 121-82-4
N-Methyl-N-(2,4,6-trinitrophenyl)nitramide Tetryl 479-45-8
Note: Analytes in bold are not identified by EPA Method 8330B.
Figure 1. Primary Method labeled chromatograms
Figure 2. Secondary Method labeled chromatograms

The primary intention of the analytical methods presented here is to support the monitoring of legacy and insensitive munitions contamination on test and training ranges, however legacy and insensitive munitions often accompany each other at demilitarization facilities, manufacturing facilities, and other environmental sites. Energetic materials typically appear on ranges as small, solid particulates and due to their varying functional groups and polarities, can partition in various environmental compartments[3]. To ensure that contaminants are monitored and controlled at these sites and to sustainably manage them a variety of sample matrices (surface or groundwater, process waters, soil, and tissues) must be considered. (Process water refers to water used during industrial manufacturing or processing of legacy and insensitive munitions.) Furthermore, additional analytes must be added to existing methodologies as the usage of IM compounds changes and as new degradation compounds are identified. Of note, relatively new IM formulations containing NTO, DNAN, and NQ are seeing use in IMX-101, IMX-104, Pax-21 and Pax-41 (Table 1)[4][5].

Sampling procedures for legacy and insensitive munitions are identical and utilize multi-increment sampling procedures found in USEPA Method 8330B Appendix A[1]. Sample hold times, subsampling and quality control requirements are also unchanged. The key differences lie in the extraction methods and instrumental methods. Briefly, legacy munitions analysis of low concentration waters uses a single cartridge reverse phase SPE procedure, and acetonitrile (ACN) is used for both extraction and elution for aqueous and solid samples[1][6]. An isocratic separation via reversed-phase C-18 column with 50:50 methanol:water mobile phase or a C-8 column with 15:85 isopropanol:water mobile phase is used to separate legacy munitions[1]. While these procedures are sufficient for analysis of legacy munitions, alternative solvents, additional SPE cartridges, and a gradient elution are all required for the combined analysis of legacy and insensitive munitions.

Previously, analysis of legacy and insensitive munitions required multiple analytical techniques, however the methods presented here combine the two munitions categories resulting in an HPLC-UV method and accompanying extraction methods for a variety of common sample matrices. A secondary HPLC-UV method and a HPLC-MS method were also developed as confirmatory methods. The methods discussed in this article were validated extensively by single-blind round robin testing and subsequent statistical treatment as part of ESTCP ER19-5078. Wherever possible, the quality control criteria in the Department of Defense Quality Systems Manual for Environmental Laboratories were adhered to[7]. Analytes included in the methods presented here are found in Table 1.

The chromatograms produced by the primary and secondary HPLC-UV methods are shown in Figure 1 and Figure 2, respectively. Chromatograms for each detector wavelength used are shown (315, 254, and 210 nm).

Extraction Methods

Figure 3. Triple cartridge SPE setup
Figure 4. A flow chart of the soil extraction procedure

High Concentration Waters (> 1 ppm)

Aqueous samples suspected to contain the compounds of interest at concentrations detectable without any extraction or pre-concentration are suitable for analysis by direct injection. The method deviates from USEPA Method 8330B by adding a pH adjustment and use of MeOH rather than ACN for dilution[1]. The pH adjustment is needed to ensure method accuracy for ionic compounds (like NTO or PA) in basic samples. A solution of 1% HCl/MeOH is added to both acidify and dilute the samples to a final acid concentration of 0.5% (vol/vol) and a final solvent ratio of 1:1 MeOH/H2O. The direct injection samples are then ready for analysis.

Low Concentration Waters (< 1 ppm)

Aqueous samples suspected to contain the compounds of interest at low concentrations require extraction and pre-concentration using solid phase extraction (SPE). The SPE setup described here uses a triple cartridge setup shown in Figure 3. Briefly, the extraction procedure loads analytes of interest onto the cartridges in this order: StrataTM X, StrataTM X-A, and Envi-CarbTM. Then the cartridge order is reversed, and analytes are eluted via a two-step elution, resulting in 2 extracts (which are combined prior to analysis). Five milliliters of MeOH is used for the first elution, while 5 mL of acidified MeOH (2% HCl) is used for the second elution. The particular SPE cartridges used are noncritical so long as cartridge chemistries are comparable to those above.

Table 2. Primary HPLC-UV mobile phase gradient method concentrations
Method run time = 48 minutes; Column temperature = 25°C
Injection volume = 50 μL; Flow rate = 1.0 mL/min
Detector wavelengths = 210, 254, and 310 nm
Time
(min)
Reagent Water
(%)
MeOH
(%)
0.1% TFA/Water
(%)
ACN
(%)
0.00 89 3 3 5
2.00 89 3 3 5
2.20 52 40 3 5
12.5 52 40 3 5
19.0 57 35 3 5
28.0 48 44 3 5
32.0 48 44 3 5
44.0 32 60 3 5
44.1 89 3 3 5
48.0 89 3 3 5

Soils

Soil collection, storage, drying and grinding procedures are identical to the USEPA Method 8330B procedures[1]; however, the solvent extraction procedure differs in the number of sonication steps, sample mass and solvent used. A flow chart of the soil extraction procedure is shown in Figure 4. Soil masses of approximately 2 g and a sample to solvent ratio of 1:5 (g/mL) are used for soil extraction. The extraction is carried out in a sonication bath chilled below 20 ⁰C and is a two-part extraction, first extracting in MeOH (6 hours) followed by a second sonication in 1:1 MeOH:H2O solution (14 hours). The extracts are centrifuged, and the supernatant is filtered through a 0.45 μm PTFE disk filter.

The solvent volume should generally be 10 mL but if different soil masses are required, solvent volume should be 5 mL/g. The extraction results in 2 separate extracts (MeOH and MeOH:H2O) that are combined prior to analysis.

Tissues

Tissue matrices are extracted by 18-hour sonication using a ratio of 1 gram of wet tissue per 5 mL of MeOH. This extraction is performed in a sonication bath chilled below 20 ⁰C and the supernatant (MeOH) is filtered through a 0.45 μm PTFE disk filter.

Due to the complexity of tissue matrices, an additional tissue cleanup step, adapted from prior research, can be used to reduce interferences[8][2]. The cleanup procedure uses small scale chromatography columns prepared by loading 5 ¾” borosilicate pipettes with 0.2 g activated silica gel (100–200 mesh). The columns are wetted with 1 mL MeOH, which is allowed to fully elute and then discarded prior to loading with 1 mL of extract and collecting in a new amber vial. After the extract is loaded, a 1 mL aliquot of MeOH followed by a 1 mL aliquot of 2% HCL/MeOH is added. This results in a 3 mL silica treated tissue extract. This extract is vortexed and diluted to a final solvent ratio of 1:1 MeOH/H2O before analysis.

HPLC-UV and HPLC-MS Methods

Table 3. Secondary HPLC-UV mobile phase gradient method concentrations
Method run time = 43 minutes; Column temperature = 25°C
Injection volume = 50 μL; Flow rate = 0.8 mL/min
Detector wavelengths = 210, 254, and 310 nm
Time
(min)
Reagent Water
(%)
MeOH
(%)
0.1% TFA/Water
(%)
ACN
(%)
0.00 75 10 10 5
2.50 75 10 10 5
2.60 39 46 10 5
9.00 39 46 10 5
9.10 33.5 51.5 10 5
15.00 35 50 10 5
15.10 43 42 10 5
33.00 30 55 10 5
33.10 75 10 10 5
43.00 75 10 10 5
Table 4. Ionization source and detector parameters
Parameter Value
Ionization Source APCI
Ionization Mode Negative
Drying Gas Temperature (°C) 350
Vaporizer Temperature (°C) 325
Drying Gas Flow (L/min) 4.0
Nebulizer Pressure (psig) 40
Corona Current (μA) 10
Capillary Potential (V) 1500
Mass Range 40 – 400
Fragmentor 100
Gain 1
Threshold 0
Step Size 0.20
Speed (μ/sec) 743
Peak Width (min) 0.06
Cycle Time (sec/cycle) 0.57

The Primary HPLC-UV method uses a Phenomenex Synergi 4 µm Hydro-RP column (80Å, 250 x 4.6 mm), or comparable, and is based on both the HPLC method found in USEPA 8330B and previous work[1][8][2]. This separation relies on a reverse phase column and uses a gradient elution, shown in Table 2. Depending on the analyst’s needs and equipment availability, the method has been proven to work with either 0.1% TFA or 0.25% FA (vol/vol) mobile phase. Addition of a guard column like a Phenomenex SecurityGuard AQ C18 pre-column guard cartridge can be optionally used. These optional changes to the method have no impact on the method’s performance.

The Secondary HPLC-UV method uses a Restek Pinnacle II Biphenyl 5 µm (150 x 4.6 mm) or comparable column and is intended as a confirmatory method. Like the Primary method, this method can use an optional guard column and utilizes a gradient elution, shown in Table 3.

For instruments equipped with a mass spectrometer (MS), a secondary MS method is available and was developed alongside the Primary UV method. The method was designed for use with a single quadrupole MS equipped with an atmospheric pressure chemical ionization (APCI) source, such as an Agilent 6120B. A majority of the analytes shown in Table 1 are amenable to this MS method, however nitroglycerine (which is covered extensively in USEPA method 8332) and 2-,3-, and 4-nitrotoluene compounds aren’t compatible with the MS method. MS method parameters are shown in Table 4.

Summary

The extraction methods and instrumental methods in this article build upon prior munitions analytical methods by adding new compounds, combining legacy and insensitive munitions analysis, and expanding usable sample matrices. These methods have been verified through extensive round robin testing and validation, and while the methods are somewhat challenging, they are crucial when simultaneous analysis of both insensitive and legacy munitions is needed.

References

  1. ^ 1.0 1.1 1.2 1.3 1.4 1.5 1.6 United States Environmental Protection Agency (USEPA), 2006. EPA Method 8330B (SW-846) Nitroaromatics, Nitramines, and Nitrate Esters by High Performance Liquid Chromatography (HPLC), Revision 2. USEPA Website    EPA Method 8330b
  2. ^ 2.0 2.1 2.2 Crouch, R.A., Smith, J.C., Stromer, B.S., Hubley, C.T., Beal, S., Lotufo, G.R., Butler, A.D., Wynter, M.T., Russell, A.L., Coleman, J.G., Wayne, K.M., Clausen, J.L., Bednar, A.J., 2020. Methods for simultaneous determination of legacy and insensitive munition (IM) constituents in aqueous, soil/sediment, and tissue matrices. Talanta, 217, Article 121008. doi: 10.1016/j.talanta.2020.121008    Open Access Manuscript.pdf
  3. ^ Walsh, M.R., Temple, T., Bigl, M.F., Tshabalala, S.F., Mai, N. and Ladyman, M., 2017. Investigation of Energetic Particle Distribution from High‐Order Detonations of Munitions. Propellants, Explosives, Pyrotechnics, 42(8), pp. 932-941. doi: 10.1002/prep.201700089
  4. ^ Mainiero, C. 2015. Picatinny Employees Recognized for Insensitive Munitions. U.S. Army, Picatinny Arsenal Public Affairs. Open Access Press Release
  5. ^ Frem, D., 2022. A Review on IMX-101 and IMX-104 Melt-Cast Explosives: Insensitive Formulations for the Next-Generation Munition Systems. Propellants, Explosives, Pyrotechnics, 48(1), e202100312. doi: 10.1002/prep.202100312
  6. ^ United States Environmental Protection Agency (USEPA), 2007. EPA Method 3535A (SW-846) Solid-Phase Extraction (SPE), Revision 1. USEPA Website    Method 3535A.pdf
  7. ^ US Department of Defense and US Department of Energy, 2021. Consolidated Quality Systems Manual (QSM) for Environmental Laboratories, Version 5.4. 387 pages. Free Download    QSM Version 5.4.pdf
  8. ^ 8.0 8.1 Russell, A.L., Seiter, J.M., Coleman, J.G., Winstead, B., Bednar, A.J., 2014. Analysis of munitions constituents in IMX formulations by HPLC and HPLC-MS. Talanta, 128, pp. 524–530. doi: 10.1016/j.talanta.2014.02.013

See Also